GIS Data Catalog

Stormwater Control Tank

View in GIS Open Data

Learn how to use GIS Open Data 🗺

Use this Data

Links

How to use in ArcGIS Pro

Sharing Status Public

Summary


Tanks are closed stormwater features typically round or half-round section, constructed of metal or plastic.

Which are used to hold or treat stormwater.

Description


Tank Component Types---Wet (Permanent Pool): A tank that features a permanent pool of water.

They are designed to optimize water quality by providing long retention times (on the order of a week or more) to settle out particles of fine sediment to which pollutants such as heavy metals adsorb, and to allow biologic activity to occur that metabolizes nutrients and organic pollutants.---Infiltration: A tank that is designed to use the hydrologic process of water soaking into the ground (commonly referred to as percolation) to dispose of stormwater.---Detention: Detention tanks temporarily.

store stormwater and typically releases flow over a few hours or a few days.---Combined (Wet and Detention): Detention tanks contain a permanent pool of water, but also have volume for temporary storage beyond the permanent pool.


Layer information

Layer Name sw_ctrl_tank_line
Subject Category Utilities
Title Stormwater Control Tank
Feature Count 887
Feature Type Line
Next Update Continually
Spatial reference EPSG:2926
Control ID 2517
Place Keywords Pacific NW, King County, WA, Washington State
Theme Keywords Utility, MS4, Stormwater, Drainage, Municipal Separate Stormwater Sewer System, NPDES Municipal Stormwater Permit, Utilitiescommunication
Supplemental Information None

Table Preview


Attribute information

OBJECTID

From Esri

Description

Internal feature number.

Domain

Sequential unique whole numbers that are automatically generated.

Shape

From King County

Description

Feature geometry.

Domain

Coordinates defining the features.

DBAssetID

From SOP Chapter 2: Database Design

Description

DBAssetID is the unique identifier that is used to tie to Cityworks, MIS, or some other database. The DBAssetID is unique for each feature class and is generated by a script that runs nightly. Users should not modify the DBAssetID.

Domain

Not Found

ComponentType

From SOP Chapter 2: Database Design

Description

Within the Puget Sound Stormwater Infrastructure Framework, Component Type is the finest classification for a structure.

Domain

Combined, Detention, Infiltration, Unknown

Diameter

From SOP Chapter 2: Database Design

Description

Diameter is the interior diameter of the tank, in inches. Diameter is recorded when the pipe is circular in shape.

Domain

Not Found

Width

From SOP Chapter 2: Database Design

Description

Width is the distance from one side of a pipe to the other side. Width is collected when the pipe is not circular in shape.

Domain

Not Found

Height

From SOP Chapter 2: Database Design

Description

Height is the distance from the top of a pipe to the bottom. Height is collected when the pipe is not circular in shape.

Domain

Not Found

MeasSource

From SOP Chapter 2: Database Design

Description

MeasSource is the source of the Diameter, WidthA/WidthB, CoverSize, Depth and Sump Depth measurements.

Domain

Field estimate, Field measurement, Plans, Unknown

EngineeredLength

From SOP Chapter 2: Database Design

Description

EngineeredLength tracks the tank length per the design from engineered plans.

Domain

Not Found

Material

From SOP Chapter 2: Database Design

Description

Material tracks the primary material that the feature is constructed of.

Domain

CMP, Concrete, Metal, Plastic

SurfaceTexture

From SOP Chapter 2: Database Design

Description

Surface Texture is the surface feel or appearance of the tank interior.

Domain

Corrugated, Smooth

FlowDirection

From SOP Chapter 2: Database Design

Description

Flow direction tracks the function of the tank in terms of direction of conveyance.

Domain

bidirectional, Downflow

Intent

From SOP Chapter 2: Database Design

Description

Intent tracks whether the infrastructure was designed primarily to convey stormwater or a natural water body.

Domain

Convey stormwater

OwnerEntity

From SOP Chapter 2: Database Design

Description

OwnerEntity tracks the owner of the particular feature.

Domain

Airport, FMD, Private, Roads, Unknown, WLRD

Jurisdiction

From SOP Chapter 2: Database Design

Description

Jurisdiction tracks the jurisdiction that governs the land that the asset resides in.

Domain

Burien, King County, Seattle, Unknown

XYSource

From SOP Chapter 2: Database Design

Description

XYSource tracks the method in which the geographic location of the asset was recorded.

Domain

CAD, Picked from aerial, Plans, Sketch, Unknown

KingCountyMS4

No Source Noted

Description

Not Found

Domain

Not Found

FieldVisitDate

From SOP Chapter 2: Database Design

Description

FieldVisitDate tracks the date that staff last visited the feature in the field.

Domain

Not Found

LastEditDate

From SOP Chapter 2: Database Design

Description

LastEditDate tracks the date that staff last edited the feature.

Domain

Not Found

DataStage

From SOP Chapter 2: Database Design

Description

DataStage tracks the status of the data as it moves through the QAQC process.

Domain

Acquire, Approved, Process

CurrentStatus

From SOP Chapter 2: Database Design

Description

CurrentStatus tracks the status of the data as it moves through the lifecycle of an asset.

Domain

Active, Retired

DataSource

From SOP Chapter 2: Database Design

Description

DataSource tracks the group, program, or process that added the data.

Domain

KCIA CAD, Roads NPDES Mapping, SWSS Mapping

FacilityID

From SOP Chapter 2: Database Design

Description

FacilityID tracks the FacilityID number that the feature is a part of.

Domain

Not Found

PlanLink

From SOP Chapter 2: Database Design

Description

When digital plans are available, PlanLink provides a hyperlink to plan files.

Domain

Not Found

GlobalID

From SOP Chapter 2: Database Design

Description

GlobalID is a 36 character string that ArcGIS uses to uniquely identify features or table rows within a geodatabase and across geodatabases.

Domain

Not Found

AssetID

From SOP Chapter 2: Database Design

Description

AssetID is the unique identifier that is used to tie to Cityworks, MIS, or some other database. The AssetID is unique for each feature class and is generated by a script that runs nightly. Users should not modify the AssetID.

Domain

Not Found

PAA

From SOP Chapter 2: Database Design

Description

PAA tracks which Potential Annexation Area an asset intersects, if applicable.

Domain

Not Found

CCTVInspectionDate

From King County

Description

Most Recent CCTV Inspection tracks the date of the most recent CCTV inspection.

Domain

Not Found

ReducerCount

From King County

Description

Reducer Count tracks the number of reducers in the tank.

Domain

Not Found

ReducerMaterial

From King County

Description

Material tracks the primary material that the reducers are constructed of.

Domain

Not Found

ReducerDiameter

From King County

Description

Reducer Diameter is the diameter of the reducer in inches.

Domain

Not Found

ReducerEngLength

From King County

Description

Reducer Engineered Length (ft) tracks the reducer length per the design from engineered plans.

Domain

Not Found

Shape.STLength()

From ESRI

Description

Shape is used by ArcGIS to store the geometry of a feature.

Domain

Not Found


Contact information

Maintained by DNRP - Water and Land Resources
Primary Harkeerat Kang

Harkeerat.Kang@kingcounty.gov


Terms of Use

Summary


Tanks are closed stormwater features typically round or half-round section, constructed of metal or plastic.

Which are used to hold or treat stormwater.

Description


Tank Component Types---Wet (Permanent Pool): A tank that features a permanent pool of water.

They are designed to optimize water quality by providing long retention times (on the order of a week or more) to settle out particles of fine sediment to which pollutants such as heavy metals adsorb, and to allow biologic activity to occur that metabolizes nutrients and organic pollutants.---Infiltration: A tank that is designed to use the hydrologic process of water soaking into the ground (commonly referred to as percolation) to dispose of stormwater.---Detention: Detention tanks temporarily.

store stormwater and typically releases flow over a few hours or a few days.---Combined (Wet and Detention): Detention tanks contain a permanent pool of water, but also have volume for temporary storage beyond the permanent pool.


Contact information

Maintained by DNRP - Water and Land Resources
Primary Harkeerat Kang

Harkeerat.Kang@kingcounty.gov


Terms of use and copyright


Change history

10/23/2015

Feature class created and data imported from various county sources.